CO2 Gas Sensor for OEM / CO2 Gas Sensor for Industrial

Use of CO2  (carbon dioxide) gas sensors in food processing extends the storage and usable shelf life of both fresh and shelf stable food products. In meat processing, C02 gas sensors assist in retaining the natural meat color and inhibits bacterial growth.

The most common reason for use of CO2 gas sensors is to exclude oxygen (O2) from the atmosphere contained inside the storage packaging. When oxygen levels can be dropped below 2.0%, the amount of deleterious oxidation reactions in stored foods can be greatly decreased resulting in longer palatability and nutritional shelf live.

A less common, but very important use for CO2 gas sensors is fumigation. This is the killing or retarding of insect life contained in the food product.

Areas of Application:
Integrated Systems, Geothermal, Space Experiments, Metal Heat Treating, Industrial, Flue Monitoring, and Overseas Shipping Containers.


Found 32 results:

Model Part Number
Sensor Type Input Power Digital Output Analog Output Type
0.2% CO2 MONITOR MODEL 2015SPI-1    030558    Sample Draw    12 VDC    16 BIT    0-1V    DIGITAL   
0.5% CO2 MONITOR MODEL 2008DHL    030154-.5    Diffusion Head    12 VDC    -    4-20mA
0-1V   
ANALOG   
0.5% CO2 MONITOR MODEL 2008LRTB-24VDC    030401-.5    Diffusion Head    12 VDC    -    4-20mA
0-1V   
ANALOG   
1% C02 MONITOR MODEL 2008DHL    030154-1    Diffusion Head    12 VDC    -    4-20mA
0-1V   
ANALOG   
1% CO2 MONITOR MODEL 2008LRTB-24VDC    030401-1    Diffusion Head    12 VDC    -    4-20mA
0-1V   
ANALOG   
2% CO2 MONITOR MODEL 2015SPI-1N    030713    Sample Draw    12 VDC    16 BIT    NO
SWITCHES   
DIGITAL   
2% NH3 MONITOR MODEL 2024    030406    Diffusion Head    14-24 VDC    -    4-20mA
0-5V   
ANALOG   
5% CO2 MONITOR MODEL 2008DHH    030153-5    Diffusion Head    12 VDC    -    4-20mA
0-1V   
ANALOG   
5% CO2 MONITOR MODEL 2008HRTB 24V    030272-5    Diffusion Head    12 VDC    -    4-20mA
0-1V   
ANALOG   
5% CO2 MONITOR MODEL 2008SDH-P    030602-5    Sample Draw    12 VDC    -    4-20mA
0-1V   
ANALOG   
10% CO2 MONITOR MODEL 2008DHH    030153-10    Diffusion Head    12 VDC    -    4-20mA
0-1V   
ANALOG   
10% CO2 MONITOR MODEL 2008SDH    030105-10    Sample Draw    12 VDC    -    4-20mA
0-1V   
ANALOG   
10% CO2 MONITOR MODEL 2008SDH-P    030602-10    Sample Draw    12 VDC    -    4-20mA
0-1V   
ANALOG   
15% CO2 MONITOR MODEL 2008SDH    030105-15    Sample Draw    12 VDC    -    4-20mA
0-1V   
ANALOG   
15% CO2 MONITOR MODEL 2008SDH-P    030602-15    Sample Draw    12 VDC    -    4-20mA
0-1V   
ANALOG   
20% CO2 MONITOR MODEL 2007DHH-R    030390-20    Diffusion Head    12 VDC    -    0-1V    ANALOG   
20% CO2 MONITOR MODEL 2008HRTB 24V    030272-20    Diffusion Head    12 VDC    -    4-20mA
0-1V   
ANALOG   
20% CO2 MONITOR MODEL 2008SDH    030105-20    Sample Draw    12 VDC    -    4-20mA
0-1V   
ANALOG   
20% CO2 MONITOR MODEL 2008SDH-P    030602-20    Sample Draw    12 VDC    -    4-20mA
0-1V   
ANALOG   
20% CO2 MONITOR MODEL 2015DH    030147    Diffusion Head    12 VDC    -    0-1V    ANALOG   
20% CO2 MONITOR MODEL 2208    030630    Sample Draw    12 VDC    -    4-20mA
0-5V   
DIGITAL   
3-20% CO2 MONITOR MODEL 2008SDH-5V    030443    Sample Draw    12 VDC    -    4-20mA
0-1V   
ANALOG   
20% CO2 MONITOR MODEL 2005SPI-2    030546    Diffusion Head    12 VDC    16 BIT    0-1V    DIGITAL   
20% CO2 MONITOR MODEL 2015SPI-3    030545    Sample Draw    12 VDC    16 BIT    0-1V    DIGITAL   
100% CH4 MONITOR MODEL 2015SPI-4N    030712    Sample Draw    12 VDC    16 BIT    NO
SWITCHES   
DIGITAL   
100% CO MONITOR MODEL 2015SPI-CO-N    030714    Sample Draw    12 VDC    16 BIT    NO
SWITCHES   
DIGITAL   
100% CH4 MONITOR MODEL 2015SPI-4    030555    Sample Draw    12 VDC    16 BIT    0-1V    DIGITAL   
5% TO 100% CH4 MONITOR MODEL 2008SDH-5V    030438    Sample Draw    12 VDC    -    4-20mA
0-1V   
ANALOG   
100% CO MONITOR MODEL 2015SPI-CO    030560    Sample Draw    12 VDC    16 BIT    0-1V    DIGITAL   
100% CO2 MONITOR MODEL 2015SPI-100    030734    Sample Draw    12 VDC    16 BIT    0-1V    DIGITAL   
3,000PPM R-22 MONITOR MODEL 2024    010077    Diffusion Head    14-24 VDC    -    4-20mA
0-5V   
ANALOG   
3,000PPM REFRIGERANT MONITOR MODEL 2024R    010098    Diffusion Head    14-24 VDC    -    4-20mA
0-5V   
ANALOG   




 


Home | Press Releases | History | Mission/Vision Statement | Employment | OEM Industrial
OEM Biotech | Health & Safety | HVAC | Greenhouse | Process Control | Data Sheets/Spec Sheets